Nominal Pressure:
16 bar
Display Range:
0.1 litres to 9999 cubic meters
Approval:
Certified and approved by the National Regulator for Compulsory Specifications (NRCS) in accordance with SANS 1529- 1:2006 and the provisions of chapter 5, section 22(1) and 22(2)(a) and (b) of the Legal Metrology Act (Act 9 of 2014).
Mechanical Data:
- Nominal Diameter 15mm 20mm
- Nominal Flow Rate (qn) ±2% mᵌ/h 1.5 2.5
- Minimum Flow Rate (qmin) (Q1) ±5% l/h
- Nominal Working Pressure (Pn) kPa 1600 1600 Pressure loss group of meter P100
- Working Temperature Range °C 0.1°C - 50°C 0.1°C - 50°C N
Dimensions:
- H x L x W: 32cm x 11cm x 17cm
- Weight: 2.5kg
Wall Mounting Specifications:
- Class C, 15mm x 114mm
- Pulse output, non-return valve & strainer inside meter
- External Connections Female BSP & Male BSP
Stop Valve:
- 15mm ball valve
- Plastic ball valve (3 way trickle flow)